Wireless Programmable Digital Thermostat - Instruction Manual

Modified on Fri, 8 Nov at 12:39 PM

Applicable to products with part number: 400617G, 400617B, 400617C




Index






Get to know your wireless programmable digital thermostat



Your thermostat unit may be placed in any room in the home.


Large LCD screen.


Shows the ambient temperature and target temperature, in addition to the time.


It has an indicator of low battery.


Maintains configuration and programming if a power failure occurs.


It has Antifreeze protection y Open Windows feature, to control the comfort of your home in case of sudden drops in temperature.


Easy installation and maintenance.




Technical data



REFERENCE

400617B / 400617C / 400617G 

THERMOSTAT SUPPLY

4 AAA batteries

RECEIVER POWER

100-240VAC / 50-60Hz

TEMPERATURE ADJUSTMENT RANGE5ºC-35ºC
TEMPERATURE MEASUREMENT RANGE
5ºC-50ºC

TEMPERATURE MEASUREMENT ACCURACY

0.1ºC

TEMPERATURE ADJUSTMENT ACCURACY

0.5ºC

WIRELESS RANGE
100m without obstacles
FREQUENCY868MHz (Bidirectional FSK)
MAXIMUM POWER TRANSMITTED
<20dBm

OPERATING TEMPERATURE

0ºC-50ºC

STORAGE TEMPERATURE

-20ºC~+50ºC

WORKING HUMIDITY

≤ 95% RH






















Device components and buttons




Thermostat buttons


(1) Wake up screen 

(2) Menu / Toggle between manual and programming mode 

(3) Settings / Time display

(4) Power / Confirm

(5) Upload / More

(6) Lower / Less




Thermostat Screen Icons


(7)  days of the week 

(8-11) Programming periods 

(12) Thermostat - receiver connection status 

(13) Programming mode

(14) manual mode

(15) Room temperature

(16) Boiler activity

(17) Antifreeze mode
(18) Low battery
(19) Function setting mode
(20) Time setting mode
(21) Target temperature / time




Installation



(1) Lift the receiver cover with the help of a screwdriver.

(2) Screw to the wall and take the cables out through the central hole. 

(3)Connect the receiver to the boiler, taking into account the contacts NO and COM, L and N, and plug it into the electrical current.

(4) Fix the upper case and complete the installation.

(5) Put the batteries in the thermostat.

(6)The thermostat and receiver will pair automatically, with a solid wireless icon appearing on the screen Icono

Descripción generada automáticamente*.





* You will only have to pair the thermostat and receiver manually if the wireless iconIcono 
Descripción generada automáticamenteflashes.




Manual pairing between thermostat and receiver



You will only have to pair the thermostat and receiver manually if the wireless iconIcono 
Descripción generada automáticamenteflashes.



(1) Press the center buttonIcono

Descripción generada automáticamenteof the receiver only once to turn it off, so that the red light on the right does not remain on.

(2)Press and hold the center buttonIcono

Descripción generada automáticamenteon the receiver until a solid orange light appears in the indicator light on the left.

(3)On the thermostat, press and hold the center buttonIcono

Descripción generada automáticamentefor 3 seconds, until appears “OFF”on the screen.

(4) On the thermostat, press and hold the center buttonIcono

Descripción generada automáticamentefor 3 seconds, until appears “RF1”on the screen. Afterwards it will start flashing.

(5) When “RF1”flashes, press the center buttonjust once. will appear “---”and then “01”on the screen. Finally it will flash and appear again “OFF”.

(6)Press the center buttonon the receiver once to turn it on, so that the red light on the right appears. Press the center buttonthermostat once to turn it on.





Increase the target temperature of the thermostat above the ambient temperature using the Icono 
Descripción generada automáticamente arrows and confirm it with the thermostat'sIcono 
Descripción generada automáticamentebutton. You will see that the Icono 
Descripción generada automáticamente icon remains fixed on the screen.    




Receiver lights color code



PAIRING STATUS LIGHT


FLASHES FAST in YELLOW:

The thermostat is communicating with the receiver.


FLASHES SLOWLY in YELLOW:

The thermostat has not been paired correctly.

 

POWER LIGHT


FIXED in RED:

The thermostat is on.



FIXED in GREEN:

The thermostat forced start is active.



WARMING STATE


FIXED in GREEN:

The ignition order is being sent to the boiler.


NO LIGHT:

The ignition order is not being sent to the boiler.





Settings and configuration



From the thermostat configuration menu you can adjust some parameters that will adapt the device to your needs. To access the menu, follow these steps:


On the thermostat, press and hold the center buttonfor 3 seconds to access the configuration menu. 


On the thermostat, press and hold the center button Icono 
Descripción generada automáticamentefor 3 seconds until "OFF" appears on the display.
On the thermostat, press and hold the center buttonfor 3 seconds to access the configuration menu.  

You must use the arrows to modify the desired values.
You must use the buttonto move to the next configurable parameter. Then you must press Icono 
Descripción generada automáticamenteto confirm the changes and exit the menu.



Please note that if no buttons are pressed for more than 10 seconds, the thermostat will exit the settings mode without saving changes.


Below we show you each parameter and explain its operation in detail:



FUNCTION 1: CALIBRATE TEMPERATURE DIFFERENTIAL 

It is possible that we need to adjust the temperature differential to compensate the temperature shown by the thermostat with respect to the “real” temperature (for example, the one shown by a thermometer that we want to take as a reference).

Calibrating the temperature differential also allows us to adjust the temperature whenIn a room we have a small temperature difference between one place and another.
FUNCTION 2: MAXIMUM TEMPERATURE LIMIT

We can define a maximum temperature limit, so that a higher temperature cannot be programmed.


For example, if we set "25ºC" as a limit, we will not be able to select a temperature beyond that set limit.
FUNCTION 3: MINIMUM TEMPERATURE LIMIT

We can define a minimum temperature limit, so that we cannot lower it below the temperature that we configure.
 
For example, if we select "10º" as the lower limit, we could not select one below this set limit.

FEATURE 4: SCREEN DISPLAY TIME

We can adjust the time in which the screen remains on. This can be 5, 10 or 15 seconds.

You cannot select a different period or configure the screen to stay on permanently.


FUNCTION 5: HYSTERESIS

Hysteresis is a temperature range that determines the starts and stops of the boiler once the desired temperature is reached. If the desired temperature were, for example, 22ºC and there was no hysteresis margin, the boiler would start as soon as there was an ambient temperature difference of 0.1ºC (21.9ºC) with respect to the desired temperature. This would make the boiler start and stop very frequent, making the operation of the thermostat very inefficient from an energy point of view.

However, with the hysteresis adjustment you can define a temperature differential for start-up of between 0.5ºC – 3ºC. So, if the desired temperature is set to 22ºC and a hysteresis of 1ºC, the boiler will operate until the ambient temperature reaches 23ºC and will not be activated again until the ambient temperature drops 1ºC below the desired temperature (21ºC). . This reduces frequent start-ups and stops and contributes to energy savings in your home.
 
FUNCTION 6: ON/OFF PROGRAM

Enables or disables the use of programming mode.
FUNCTION 7: PROGRAMMING PERIODS/TIME SLOTS

Using this option we can select the configuration of hourly farms that we want for each day (4 or 6).

FUNCTION 8: SMART FUNCTION ON/OFF

Through this parameter you can activate or deactivate the intelligent function of the thermostat. That is, the early ignition of the boiler so that the programmed temperature is reached at the desired time, instead of starting the boiler at the stipulated time.
FUNCTION 9: ANTI-FREEZE FUNCTION

This configuration allows us to activate or deactivate the frost protection mode. When this option is active, if the room temperature is below 5ºC, the thermostat starts frost protection mode. When the temperature exceeds 8ºC the boiler will stop. Under this operating mode no other options will be executed, for example, programming.



OTHER FUNCTIONS


OPEN WINDOWS FUNCTION

The Open Windows function turns off the heating automatically if the room temperature drops 4.5ºC in 4 minutes. If the temperature rises again by 1.5ºC or more than 48 minutes pass without any change, the Open Windows function is automatically deactivated. You can also manually turn off the Windows Open feature by pressing any button on the thermostat.

FORCED START-UP

The Forced Start function allows you to turn on the heating if the thermostat unit is damaged or unusable. To activate it, press the center button of the receiver for more than 8 seconds. You will see a solid green light appear on the indicator light on the right of the receiver and you will hear the relay activating. To deactivate the relay, press the center button once of the receiver.




Time adjustment



Your thermostat has a factory default time and schedule, but you can modify both settings to suit your needs and current calendar. To set the time you must follow these steps:



Press and hold the watch button for a few seconds Icono

Descripción generada automáticamentethermostat, to enter the time setting screen.
 

Now in the time settings, use the arrows Imagen en blanco y negro

Descripción generada automáticamente con confianza bajato select the time and the clock button Icono

Descripción generada automáticamenteto confirm.



A "Y" will appear in the center of the screen to set the year. Use the arrowsImagen en blanco y negro Descripción generada automáticamente con confianza bajato select the correct year and confirm by pressing Icono

Descripción generada automáticamente.

A "T" will appear in the center of the screen to set the time, choosing first the minutes and then the hour. Use the arrowsImagen en blanco y negro Descripción generada automáticamente con confianza bajato choose and confirm by pressingIcono

Descripción generada automáticamente.


A "d" will appear in the center of the screen to set the day. Use the arrowsImagen en blanco y negro Descripción generada automáticamente con confianza bajato select the day and confirm by pressingIcono

Descripción generada automáticamente.




A "m" will appear in the center of the screen to set the month. Use the arrowsImagen en blanco y negro Descripción generada automáticamente con confianza baja to select the month and confirm by pressingIcono

Descripción generada automáticamente.

After completing all the steps, press Icono Descripción generada automáticamente to confirm and exit the time setting screen.




Manual thermostat programming



First, check that you have configured the configuration parameters correctly 6 (ON / OFF programming) and 7 (Programming periods / Time slots).

Subsequently, access the programming menu and follow these steps:


1. With the thermostat on, press and hold the button3 seconds.2. You must use the arrows to modify the desired values.3. You must use the buttonto go to the next configurable parameter (programming periods, hours and temperatures).


Now we will tell you how to configure the temperature and time of each programming period using the first one as an example:Icono

Descripción generada automáticamente. Remember to repeat the following steps as many times as the programming periods you have chosen in the configuration.


1. With the thermostat on, press and hold the buttonApproximately 3 seconds to access the programming menu.


2. Use the arrowsto choose the day or set of days (M-S, M-F, S-S) on which the schedule will be active. press the buttonto continue.


3. Use the arrowsto choose the start time of the first scheduling periodIcono

Descripción generada automáticamente. press the buttonto continue.


4. Use the arrowsto choose the desired temperature of the periodIcono

Descripción generada automáticamente. press the buttonto continue.


5. You will see that now the thermostat enables the next programming period so that you can configure them in the same way as you did with the first one.Icono

Descripción generada automáticamente.


6. Adjust the values of the rest of the programming periods Dibujo de una persona

Descripción generada automáticamente con confianza bajao according to your needs.


7. When you finish setting up the last scheduling periodIcono

Descripción generada automáticamentepress the buttonto confirm the changes and save the programming.


Example of programming in 4 sections:



Your boiler will turn on if the ambient temperature in your home is below 20ºC from 6:00 until 8:00. Between 8:00 and 18:00, your boiler will turn on if the ambient temperature in your home is below 16ºC. Between 18:00 and 22:00, your boiler will turn on if the ambient temperature in your home is below 20ºC. Between 22:00 and 06:00 the next day, your boiler will turn on if the ambient temperature in your home is below 16ºC.


Tip: If you want less than 4 programming periods throughout the day, repeat the same desired temperature in some of the intermediate periods.




Factory Reset Wireless Digital Thermostat



RESET FACTORY SETTINGS


1. On the thermostat, press and hold the center button for 3 seconds until appears "OFF" on the screen.


2. Press and hold the button for 3 seconds to access the first adjustable configuration parameter.

 

3. Makeep pressing the button for 3 seconds again until appears "DEF". Afterwards it will start flashing for a few seconds and will appear again "OFF" on the screen. This will reset your thermostat's configuration settings to their factory settings. To configure them again, check the "Settings and Configuration" section.




RESET FACTORY PROGRAM


1. With the thermostat on, press and hold the button for 3 seconds.


2. Makeep pressing the button for 3 seconds again until appears "DEF". Afterwards it will start flashing for a few seconds and the temperature will appear on the screen again. In this way, your thermostat programming will have been reset to its factory settings. To configure it again, review the "Manual thermostat programming" section.




RESET PAIRING


Check the section Manual pairing between thermostat and receiver.




FULL FACTORY RESET DEVICE


If the device does not turn on or respond, press the reset button from the back of the thermostat:


 

*The notice "room ERR"indicates that the temperature sensor of your thermostat is damaged.




If you want to know more or have any difficulties, check the Knowledge base or get in touch with us to receive personalized help.

        