Programmable Digital Thermostat - Userguide

Modified on Wed, 28 Aug at 2:10 PM

Applicable to products with part number: 400616G, 400616B, 400616C




Index





Know your digital thermostat



Large LCD screen.


Displays the ambient temperature and target temperature, along with the time. 

 

It has an indicator of low battery.


Includes a low battery indicator. 


Retains settings and programming in case of a power failure. 


Features Anti-freeze protection and Open Window function, to control the comfort of your home during sudden drops in temperature. 


Easy installation and maintenance.




Technical data



REFERENCE

400616B / 400616C/ 400616G

FEEDING

4 AAA batteries

TEMPERATURE ADJUSTMENT RANGE5ºC-35ºC

TEMPERATURE MEASUREMENT ACCURACY

0.1ºC

TEMPERATURE ADJUSTMENT ACCURACY

0.5ºC

OPERATING TEMPERATURE

0ºC-50ºC

STORAGE TEMPERATURE

-20ºC~+50ºC

WORKING HUMIDITY

≤ 95% RH













Device components and buttons




Thermostat buttons


(1) Wake up screen 

(2) Menu / Toggle between manual and programming mode 

(3) Settings / Time display

(4) Power / Confirm

(5) Upload / More

(6) Lower / Less


Thermostat Screen Icons


(7)  days of the week 

(8-11) Programming periods 

(12) Programming mode

(13) manual mode

(14) Room temperature

(15) Boiler activity

(16) Antifreeze mode
(17) Low battery
(18) Function setting mode
(19) Time setting mode
(20) Target temperature/time




Installation



(1) Separate the rear cover of the thermostat. Pass the cables NO and COM through the hole and fix it to the wall with the included screws.

(2) Remove the protective plastic from the contacts NO and COM from the back of the thermostat and wire them in their respective order.

(3) Put the batteries in the thermostat and replace the cover, pressing.






Settings and configuration



From the thermostat configuration menu you can adjust some parameters that will adapt the device to your needs. To access the menu, follow these steps:



On the thermostat, press and hold the center button Icono 
Descripción generada automáticamentefor 3 seconds until "OFF" appears on the display.
On the thermostat, press and hold the center buttonfor 3 seconds to access the configuration menu.  

You must use the arrows to modify the desired values.
You must use the buttonto move to the next configurable parameter. Then you must press Icono 
Descripción generada automáticamenteto confirm the changes and exit the menu.



Please note that if you do not press any button for more than 10 seconds, the thermostat will exit setup mode without saving the changes.ios.


Below we show you each parameter and explain in detail how it works:



FUNCTION 1: CALIBRATE TEMPERATURE DIFFERENTIAL 

It is possible that we need to adjust the temperature differential to compensate the temperature shown by the thermostat with respect to the “real” temperature (for example, the one shown by a thermometer that we want to take as a reference).

Calibrating the temperature differential also allows us to adjust the temperature whenIn a room we have a small temperature difference between one place and another.
FUNCTION 2: MAXIMUM TEMPERATURE LIMIT

We can define a maximum temperature limit, so that a higher temperature cannot be programmed.


For example, if we set "25ºC" as a limit, we will not be able to select a temperature beyond that set limit.
FUNCTION 3: MINIMUM TEMPERATURE LIMIT

We can define a minimum temperature limit, so that we cannot lower it below the temperature that we configure.
 
For example, if we select "10º" as the lower limit, we could not select one below this set limit.

FEATURE 4: SCREEN DISPLAY TIME

We can adjust the time in which the screen remains on. This can be 5, 10 or 15 seconds.

You cannot select a different period or configure the screen to stay on permanently.


FUNCTION 5: HYSTERESIS

Hysteresis is a temperature range that determines the starts and stops of the boiler once the desired temperature is reached. If the desired temperature were, for example, 22ºC and there was no hysteresis margin, the boiler would start as soon as there was an ambient temperature difference of 0.1ºC (21.9ºC) with respect to the desired temperature. This would make the boiler start and stop very frequent, making the operation of the thermostat very inefficient from an energy point of view.

However, with the hysteresis adjustment you can define a temperature differential for start-up of between 0.5ºC – 3ºC. So, if the desired temperature is set to 22ºC and a hysteresis of 1ºC, the boiler will operate until the ambient temperature reaches 23ºC and will not be activated again until the ambient temperature drops 1ºC below the desired temperature (21ºC). . This reduces frequent start-ups and stops and contributes to energy savings in your home.
 
FUNCTION 6: ON/OFF PROGRAM

Enables or disables the use of programming mode.
FUNCTION 7: PROGRAMMING PERIODS/TIME SLOTS

Using this option we can select the configuration of hourly farms that we want for each day (4 or 6).

FUNCTION 8: SMART FUNCTION ON/OFF

Through this parameter you can activate or deactivate the intelligent function of the thermostat. That is, the early ignition of the boiler so that the programmed temperature is reached at the desired time, instead of starting the boiler at the stipulated time.
FUNCTION 9: ANTI-FREEZE FUNCTION

This configuration allows us to activate or deactivate the frost protection mode. When this option is active, if the room temperature is below 5ºC, the thermostat starts frost protection mode. When the temperature exceeds 8ºC the boiler will stop. Under this operating mode no other options will be executed, for example, programming.



OTHER FUNCTIONS


OPEN WINDOWS FUNCTION

The Open Windows function turns off the heating automatically if the room temperature drops 4.5ºC in 4 minutes. If the temperature rises again by 1.5ºC or more than 48 minutes pass without any change, the Open Windows function is automatically deactivated. You can also manually turn off the Windows Open feature by pressing any button on the thermostat.




Time adjustment



Your thermostat has a factory default time and schedule, but you can modify both settings to suit your needs and current calendar. To set the time you must follow these steps:



Press and hold the watch button for a few seconds Icono

Descripción generada automáticamentethermostat, to enter the time setting screen[].
 

Now in the time settings, use the arrows Imagen en blanco y negro

Descripción generada automáticamente con confianza bajato select the time and the clock button Icono

Descripción generada automáticamenteto confirm.



A "Y" will appear in the center of the screen to set the year. Use the arrowsImagen en blanco y negro Descripción generada automáticamente con confianza bajato select the correct year and confirm by pressing Icono

Descripción generada automáticamente.

A "T" will appear in the center of the screen to set the time, choosing first the minutes and then the hour. Use the arrowsImagen en blanco y negro Descripción generada automáticamente con confianza bajato choose and confirm by pressingIcono

Descripción generada automáticamente.


A "d" will appear in the center of the screen to set the day. Use the arrowsImagen en blanco y negro Descripción generada automáticamente con confianza bajato select the day and confirm by pressingIcono

Descripción generada automáticamente.


A "m" will appear in the center of the screen to set the month. Use the arrowsImagen en blanco y negro Descripción generada automáticamente con confianza baja to select the month and confirm by pressingIcono

Descripción generada automáticamente.

After completing all the steps, pressIcono Descripción generada automáticamenteto confirm and exit the time setting screen.




Manual thermostat programming



First, check that you have configured the configuration parameters correctly 6 (ON / OFF programming) and 7 (Programming periods / Time slots).

Subsequently, access the programming menu and follow these steps:


1. With the thermostat on, press and hold the button3 seconds.2. You must use the arrows to modify the desired values.3. You must use the buttonto go to the next configurable parameter (programming periods, hours and temperatures).


Now we will tell you how to configure the temperature and time of each programming period using the first one as an example:Icono

Descripción generada automáticamente. Remember to repeat the following steps as many times as the programming periods you have chosen in the configuration.


1. With the thermostat on, press and hold the buttonApproximately 3 seconds to access the programming menu.


2. Use the arrowsto choose the day or set of days (M-S, M-F, S-S) on which the schedule will be active. press the buttonto continue.


3. Use the arrowsto choose the start time of the first scheduling periodIcono

Descripción generada automáticamente. press the buttonto continue.


4. Use the arrowsto choose the desired temperature of the periodIcono

Descripción generada automáticamente. press the buttonto continue.


5. You will see that now the thermostat enables the next programming period so that you can configure them in the same way as you did with the first one.Icono

Descripción generada automáticamente.


6. Adjust the values of the rest of the programming periods Dibujo de una persona

Descripción generada automáticamente con confianza bajao according to your needs.


7. When you finish setting up the last scheduling periodIcono

Descripción generada automáticamentepress the buttonto confirm the changes and save the programming.


Example of programming in 4 sections:



Your boiler will turn on if the ambient temperature in your home is below 20ºC from 6:00 until 8:00. Between 8:00 and 18:00, your boiler will turn on if the ambient temperature in your home is below 16ºC. Between 18:00 and 22:00, your boiler will turn on if the ambient temperature in your home is below 20ºC. Between 22:00 and 06:00 the next day, your boiler will turn on if the ambient temperature in your home is below 16ºC.


Tip: If you want less than 4 programming periods throughout the day, repeat the same desired temperature in some of the intermediate periods.




Factory reset the digital thermostat



RESET FACTORY SETTINGS


1. On the thermostat, press and hold the center button for 3 seconds until appears “OFF”on the screen.


2. Press and hold the button for 3 seconds to access the first adjustable configuration parameter.

 

3. Makeep pressing the button for 3 seconds again until appears "DEF". Afterwards it will start flashing for a few seconds and will appear again "OFF" on the screen. This will reset your thermostat's configuration settings to their factory settings. To configure them again, check the "Settings and Configuration" section.




RESET FACTORY PROGRAM


1. With the thermostat on, press and hold the button for 3 seconds.


2. Makeep pressing the button for 3 seconds again until appears "DEF". Later it will start flashing for a few seconds and the temperature will appear on the screen again. In this way, your thermostat programming will have been reset to its factory settings. To configure it again, review the "Manual thermostat programming" section.



FULL FACTORY RESET DEVICE


If the device does not turn on or respond, press the reset button from the back of the thermostat:



*"room ERR" indicates that the temperature sensor of your thermostat is damaged.



If you want to know more or have any difficulties, consult the Knowledge base or get in touch with us to receive personalized help.

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article